Specifications and Reference Data
May 2016
Reference Manual
00809-0100-4530, Rev DD
268
Specifications and Reference Data
Hydrostatic testing
P1
(11)
Hydrostatic testing
★
Factory configuration
C1
Factory configuration (Configuration Data Sheet required with order, available at
)
★
Alarm limit configuration
C4
Namur alarm and saturation levels, high alarm
★
C5
Namur alarm and saturation levels, low alarm
★
C8
Low alarm
(12)
(standard Rosemount alarm and saturation levels)
★
Welding documentation
Q66
Welding Procedure Qualification Record Documentation
Q67
Welder Performance Qualification Record
Q68
Welding Procedure Specification
Safety certifications
QS
Prior-use certificate of FMEDA Data. Only available with HART 4-20 mA output (output code H).
★
QT
Safety-certified to IEC 61508 with certificate of FMEDA data.
Only available with HART 4-20 mA output (output code H).
★
Special certifications
Q4
Calibration Data Certification
★
Q8
(13)
Material Traceability Certification per EN 10204 3.1
★
QG
GOST Primary Verification Certificate
Installation options
LS
Long stud 9.8 in (250 mm) for flexible single lead probe to prevent contact with wall/nozzle.
Standard stud length is 3.9 in (100 mm) for probes 5A and 5B; 5.9 in. (150 mm) for probes 6A and 6B
★
BR
316L SST Mounting Bracket for 1½-in. NPT Process Connection (RA) (see
Transient protection
T1
Transient Protection Terminal Block. Selectable with HART 4-20 mA output (output code H). Already
included in all F
OUNDATION
Fieldbus variations.
★
Diagnostic functionality
D01
F
OUNDATION
Fieldbus Diagnostics Suite (includes Signal Quality Metrics diagnostics)
★
DA1
HART Diagnostics Suite (includes Signal Quality Metrics diagnostics)
★
Overfill prevention
U1
(14)
WHG Overfill Approval
★
Table A-16. Rosemount 5303 Level for Solids Ordering Information
The starred options (
★
) represent the most common options and should be selected for best delivery. The non-starred offerings
are subject to additional delivery lead time