PROGRAMMING (communication with PC):
– flashes ca. every 1 second. = connection with service computer
REMARKS:
●
if the signaling is not pre-programmed for a given PHONE NUMBER, the module will go to
the next set job (signaling)
●
LOG:
NORMAL STATE
-
series of 1 to 5 short flashes every ca. 2 seconds = GSM network signal level (1-min. 5 = max.)
●
- no flashes = telephone not logged in GSM network
●
FAIL:
FAIL:
NORMAL STATE
series of 1 to 10 short flashes every ca. 2 seconds = state of FAILURE
1 - low network signal level, below 2 “dashes”
2 – telephone not logged in network
3 – unsuccessful attempt to send 3 consecutive SMS messages
4 - low power supply voltage U<11V on the power supply input
5 – overloaded O1 high current output (I>1A)
6 – no communication with the module telephone
7 – PIN code error
8 – SIM card error, SIM card has been not detected by the module
9 – no communication with PSR/PSR-RF module
10 – no communication with FGR-4 module
11 – GRPR connecting error (message transmission: MMS, E-MAIL)
12 – AUX power supply output overload
13 - KBD power supply output overload
17- battery failure: disconnect or low voltage (
U<11V)
21 – O1 overload
22 – O2 overload
23 – O1 no load (>2KOhm)
24 – O2 no load (>2KOhm)
•
PROGRAMMING (communication with PC):
– flashes every ca. 0.5 second = module firmware update (communication active)
●
INCOM:
NORMAL STATE
- no lit = lack of activity of incoming calls
- lit = incoming calls or SMS
PROGRAMMING (communication with remote PC ):
- lit = connecting with remote PC via CSD (modem link)