Installation and operating manual: NEO/NEO-PS v.1.4S EN
7.7. Remote configuration of other parameters.
The configuration SMS syntax has the following format:
Where: yyyy = access code;
Parameter
Description
Example
Remarks
yyyy CODE zzzz
Altering the access code
(zzzz = new access code)
1111 CODE 1234
yyyy = present access
code
zzzz = new access code
yyyy TIME yy, mm, dd, hh,
mm
Setting, altering of date
and time (yy, mm, dd, hh,
mm = year, month, day,
hour, minutes)
1111 TIME 02, 01, 01,
12, 05
Gap (space) required
after commas
yyyy CORRECTION qsss
Correction of module clock
(q = +/- character, sss =
correction value [s])
1111 CORRECTION -002 q= +/-
sss = max. 120[s]
yyyy RESETTEST
Resetting of the
transmission test clock
1111 RESETTEST
yyyy RESTART
Restarting of modem and
module
1111 RESTART
yyyy DOWNLOADING x
Remote
activation/deactivation
of the modem connection
function
1111 DOWNLOADING 1
X = 1 function enabled
x = 0 function disabled
8.
MODULE OPERATION SATUS SIGNALING
The NEO module is equipped with an optical status signaling system. Four LED diodes mounted on the
module board display the operation status of: signaling, communication with PC, software update.
LED
Color
COMM
GREEN color
SEND
YELLOW color
LOG
BLUE color
FAIL
RED color
INCOM
YELLOW color
●
COMM:
NORMAL STATE (without signaling and programming action)
– short flashes every ca. 1 second =
satisfactory
●
SEND:
ALARM ACTION:
signaling via SMS messages and voice messages is performed according to the
following procedures:
SMS
1 flash = send SMS to NUMBER 1,
...
- 8 flashes = send SMS to NUMBER 8,
VOICE MESSAGES
- 1 flash = connection to NUMBER 1,
….
- 8 flashes = connection to NUMBER 8,
42