Installation and operating manual: NEO/NEO-PS v.1.4S EN
logical function 'xor' (
XOR,
B
A
Y
⊕
=
, where Y = output, A/B = input/output).
It is a logic circuit which has the signal value “1” at the output only when one of input signals is “1”. In case
when signals equal “0” or more than one signal is “1”, then the signal at the output equals “0”.
A
B
Y
0
0
0
0
1
1
1
0
1
1
1
0
6.5 OPTIONS bookmark
Options: Options 1, Options 2 (changed on the side belt) permit configuration of::
•
the transmission test
•
power supply control DC and AC (only NEO-PS)
•
counters limiting quantity and signaling duration times (costs)
•
time duration of: connections, input delays, CLIP, waiting for SMS message sending
•
access codes to chosen security code protected functions
•
reactions to incoming calls
•
temperature measurement options (thermostat)
•
timers
6.5.1 TRANSMISSION TEST
Option enables determination of
a
testing method of the module connection with the GSM network. To
activate the options, mark TRANSMISSION TEST.
REMARKS
:
The transmission test is sent only to the first telephone number (entered in the
NUMBERS bookmark)
•
TEST TYPE /ACKNOWLEDGEMENT TYPE
– option enables choice of a test type: SMS, CLIP or
SMS STAN (see. Command
STATUS)
•
TEST SENDING
– option enables a choice of: cycle point or hour of test sending,
•
EVERY HOW MANY HOURS
– determines the repeating cycle of test sending - in hours. The cycle
countdown begins from the module restart.
23