Installation and operating manual: NEO/NEO-PS v.1.4S EN
6.5.6 INCOMING CALLS
This option enables module reaction time setting to
incoming calls, which are listed as “Telephone numbers”.
•
DO NOT REACT
– module does not take any action
•
REJECT AND CALL BACK AFTER
– incoming call
will be rejected after set time [s], and the CLIP will be
performed to the calling number.
•
REJECT AFTER
– the incoming call will be rejected after a
set time [s].
•
RECEIVE AFTER
– the incoming call will be received after a set time [s]. If a speech synthesizer is
connected, the message will be played
REMARKS:
•
the connection time is counted from the first ring detection
•
incoming calls from other numbers are immediately rejected.
6.5.6 TEMPERATURE SENSOR
Options enable configuration of temperature measurement function with the use of TSR-1 detector.
•
PARAMETER
– high temperature (H), low (L), sensor failure
•
TEMPERATURE VALUE
– the temperatures shall be entered in Celsius °C within -55°C to +125°C
(var/- 1°C),
•
SMS CONTENT –
SMS content shall be entered in the bookmark and it is sent after event occurrence
(reaching determined value). Maximal SMS length is 20- characters. Do not use special characters (e.g.
Polish letters).
•
CALL
- marking the option triggers calling (voice notification) after particular event detection
•
VSR -
this column enables configuring the content of voice messages, in cooperation with the VSR-2
Voice Synthesizer.
Enter the characters corresponding to the numbers of registered voice messages and/or object sound
detectors:
- messages: 0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,F
(message maximum time: 0-7 = 16s; 8-F = 8s.)
- audio module (microphone): m
It is possible to sum the content of message by entering a number of characters (no more than 5),
separated with a comma. The messages will be presented in a sequence, according to the entry in the
bookmark. For H and L temperature each entry can be configured separately.
•
NUMBERS 1÷8 –
in the bookmark telephone numbers shall be mark for SMS and/or VOICE
notification
•
ADDITIONAL OPTIONS
- „saving temperature value to events memory after every 30 minutes”: choosing the option activates
26