Installation and operating manual: NEO/NEO-PS v.1.4S EN
●
TIME [s]
Determines operation time [s] in the output MONO mode, where the maximum time duration is 9000
seconds.
●
SMS ON
Enter the SMS message content in the tab. The content will cause the activation of the given output (On
X by default, where X = output number). The maximum length of the SMS message is 20 characters.
Do not use special characters (for example: letters of the local alphabet).
●
SMS OFF
Enter the SMS message content in the tab. The content will cause deactivation of the given output (OffX
by default, where X = output number). The maximum length of the SMS message is 20 characters. Do
not use special characters (for example: letters of the local alphabet).
●
CODE REQUIRED
Marking this option, in order to control a particular output with SMS messages, will require providing an
ACCESS CODE (OPTIONS tab) in the SMS message content, as an addition to the SMS ON/SMS OFF
content.
●
SWITCHING VIA
Defines which events control output status, marking a few options creates LOGIC SUM (OR) of these
events (it means that the output is active when at least one event happens), it enables connecting e.g.
Output control via SMA or CLIP.
•
SMS,
output control via SMS (command or command + code according to configuration) is
permitted when option is marked
•
CLIP
, output control by making a short connection with the module telephone number. The
function is accessible when control is enabled by selecting numbers entered in the “Telephone
numbers” fields in the “Numbers authorized to control CLIP” panel, or by entering any number. In
addition, the module reaction to incoming calls can be defined by using the “Incoming calls” option
•
ALARM
output is active when alarm is triggered. (def. normal input)
•
ARMED
output active (indicator) armed when module counter has finished countdown time to exit.
When this option is active, the settings in the “
TIME [s]
” field are ignored.
•
ENTRY TIME
, output is active during module entry countdown time (def. ARM/DISARM input,
delayed)
•
EXIT TIME
output active during module exit countdown time
•
IMPULSE ARMING ACKNOWLEDGEMENT
option activates ARM/DISARM module standby time
acknowledgment. Function available only for O1 output.
Signaling: 1 short signal – standby on, 2 short signals: standby off.
•
INPUT/OUTPUT VIOLATION
– the output is active when the input is violated or output activated.
The mask for the inputs/outputs, which activate a particular output, can be configured in the
ACTIVATING INPUTS/OUTPUTS.
•
FAILURE
– the output is activated after a failure has occurred.
•
AC
LOST–
the output is activated after a decay in the AC supply has occurred (MGSM 4.0-PS only),
the time of delay for signaling “no AC supply” (5s – 1,000 min) is configured in the OPTIONS tab.
•
TAMPER
– the output is activated when the 2EOL/NC or 2EOL/NO line has been sabotaged.
•
TIMER x
output that is controlled by a chosen timer (activated/dis-activated, see
OPTIONS>Options 2)
REMARKS:
•
marking an option in the OPTIONS bookmark->Options 2: High temperature OUT5
and/or Low temperature OUT6 has got higher priority than in the settings SWITCHING
VIA:...Controlling OUT5 and OUT6 outputs with a temperature parameter enables
creating a mono block thermostat.
6.4.2 CLIP CONTROL TELEPHONES