Installation and operating manual: NEO/NEO-PS v.1.4S EN
The transmission cycle countdown reset with immediate testing (CLIP or SMS) is possible. To
perform reset, send a
RESETTEST
SMS, the module will reply with a transmission test and next
test will be performed after a set number of hours.
•
EVERYDAY ON THE HOUR
– determines the hour of test performance
This option requires the module clock to be set via the PARTNER GSM software or remotely by
using the TIME SMS.
e.g. Reset transmission cycle SMS:
xxxx RESETTEST
, where xxxx – access code (e.g. adam)
REMARKS:
•
the module restart is permitted by using an SMS RESTART message. This command is
not acknowledged with a restore message.
e.g. The module restarting SMS:
xxxx RESTART,
where xxxx – access code (e.g. adam)
•
CLOCK CORRECTION
– if the internal module clock reading differs from the real value, the daily
average should be computed and set in the bookmark. This function p/- 120 seconds time
compensation per day.
The clock correction can be also performed by using the
CORRECTION
SMS.
e.g. the clock correction SMS:
xxxx CORRECTION zyyy
, where xxxx – access code (e.g. adam), z – correction character (+or-), yyy –
correction value in seconds
(example: adam CORRECTION –10 = 10 seconds per 24 hours delay)
•
SMS CONTENT
SMS content to be sent as test information (“GSM module OK” by default) should
be entered in the bookmark.
REMARKS:
•
the maximum number of characters 20, do not enter national characters
•
the module can be tested via an SMS message by sending the module access code - if
the code is identical to the one in the module memory, it will reply by sending a test
SMS.
e.g. „test on demand”:
xxxx
, where xxxx – access code (e.g. Adam) (example: adam = reply: GSM module OK
6.5.2 FAILURES
The module permanently monitors the value of the supply voltage. If the supply voltage, measured at
module supply terminals (+12V, GND), falls below the value of 11 VDC (or returns above the value of 11V),
such information can be sent via an SMS message.
•
SUPPLY FAILURE
- the SMS content signaling a power supply drop below 11V should be entered
in the bookmark.
•
SUPPLY RESTORE
- the SMS content signaling a power supply restore above 11V should be
entered in the bookmark.
•
NO AC SUPPLY
– enter the SMS message content corresponding to the decay of AC voltage
(NEO-
PS only)
in the tab. The time of signalization delay is configured in the DELAY [min] tab (in 5s –
1,000min range).
•
AC SUPPLY RETURNED
enter the SMS message content that signals the return of AC supply
voltage in the tab.
REMARKS:
•
The ALARM SMS content is sent only to the first telephone number (entered in the
„NUMBERS” bookmark).
•
Only one information can be entered and a missing SMS implies that no message
regarding a given event will be sent.
6.5.3 COUNTERS
The number of sent SMS messages and the number of
telephone calls can be set in this bookmark. Counters may serve
to limit costs during failures of input devices (damaged alarm
sensor, power supply failure etc.).
24