Installation and operating manual: NEO/NEO-PS v.1.4S EN
7. Connect the external antenna to the FME-F connector.
8. Switch on the module power supply.
9. Connect the cable between the service computer and the RS TTL socket.
10. Configure the module according to requirements.
11. Perform tests.
12. Disconnect the wire form RS TTL socket.
REMARKS:
•
Observe all possible precautionary measures against static discharge to protect the
electronic components.
•
Do not switch on the power supply when the external antenna is not connected.
•
When installing in O-R2, O-RH and other dedicated housings, intended for using with
the mains power supply (with transformer), do not connect the N (“zero”) cable to
the PE grounding clamp of the 230V AC mains power supply. Connecting the N cable
to the PE clamp may damage the electronic components, as GND is then directly
connected to PE! If there is no separate grounding cable provided, the clamp should
be left disconnected.
•
In pt. 2.b pins should be inserted in the module PCB board (4 pcs.) Remove the
protective foil from the adhesive layer, place on the inside degreased housing surface
and press lightly.
4.2. CONNECTING THE VOICE SYNTHETIZER OR AUDIO MODULE.
The NEO/NEO-PS+ module has a VSR socket intended for connecting the VSR-2, VSR-1 and the AMR-1 audio
or other (e.g. utilized in CCTV) voice synthesizer modules, provisioned for listening in on the object.
•
The voice synthesizer can record and relay a voice command when an event (alarm) occurs in the
system. Replay is performed automatically after establishing voice communication. The message is
repeated cyclically until the connection is terminated. The voice synthesizer should be connected
directly to the VSR connector and the message recorded after the power supply is switched on (built in
microphone). The message is stored even after the power supply is disconnected (disconnected
synthesizer).The synthesizer has got a MINIJACK output for listening to the recording.
•
Listening in on the object can be accomplished with the AMR-1 module, when the alarm is triggered or
when a voice message is established (connecting with the module from authorized lines). To connect
the MGSM 3.5/3.5-PS, MGSM 5.0/5.0-PS, VSR-2 and AMR-1 (or other) modules, the 5-pin plug should
be used. The connections should be performed, as in the diagram, using the microphone cable or
twisted UTP pair over small distances.
VSR, AUDIO-IN, S-M
DESCRIPTION
1
GND – 0V, power supply ground
2
AUDIO SIGNAL IN– audio signal input (MIC)
3
SYNTHESIZER TRIGGER - 5V during the alarm,
voice message (period 20s)
4
AUDIO SIGNAL OUT– audio signal output (SPK)
5
12V – voice synthesizer or audio module power
supply
7