Installation and operating manual: NEO/NEO-PS v.1.4S EN
returning to a particular input
alarm”
characters
np.
e.g.1:
yyyy I1 EOL INFO TIME 1000 SMS 11000000 CALL 10000000 SMSV “Alarm” SMSR “ Restore
alarm”
e.g.
2:
yyyy I2 NC 24H TIME 1000 SMS 11000000 CALL 01000000 SMSV “Panic” SMSR “Restore
panic”
yyyy = acces code
7.3. Remote configuration of OUTPUTS
The configuration SMS syntax has the following format:
yyyy Ox [parameter1 parameter2 parameter3 parameter4]
Where:
- yyyy = access code, Ox = output with the no. x = {1..3}
Parameter
Description
Example
Remarks
NO
NC
Input polarization
(see paragraph 6.4.1)
NO
MONO
BI
Output operation mode
(see paragraph 6.4.1)
MONO
TIME tttt
The time of output operation in
MONO mode
TIME 1500
tttt = time in seconds [s]
Maximum time is 9,000s
ACTIV
xxxxxxxxxxx
The mask for activating the output,
according to the ACTIVATE VIA tab
and the sequence: SMS, CLIP,
ALARM, armed, TIME FOR ENTRY,
TIME FOR EXIT, ARMING
CONFIRMATION BY IMPULSES,
INPUT VIOLATION, FAILURE, NO AC
SUPPLY, SABOTAGE
ACTIV
110000000100
0
x = 1 option active
x = 0 option inactive
- Marking a few options results
in output activation according to
the selected logical function (the
logical function OR – factory
settings)
SMSON “aaaa”
The content of the SMS message
which activates a particular output
SMSZAL “pump
on”
“aaaa” = maximum 20
characters
SMSOFF “aaaa”
The content of the SMS message
which deactivates a particular
output
SMSWYL “pump
off”
“aaaa” = maximum 20
characters
CLIP xxxxxxxxx
The mask of the numbers
authorized to perform CLIP control
of a particular output (the sequence
xxxxxxxxxxx = TEL1…TEL8… EACH)
CLIP
110000000
x = 1 control is active
x = 0 control is blocked
Example:
yyyy O1 NO MONO TIME 100 ACTIVE 11000001000
yyyy = access code
7.4. Remote configuration of TRANSMISSION TEST.
The configuration SMS syntax has the following format:
yyyy TEST [parameter1 parameter2 parameter3.......]
Where:
- yyyy = access code;
Parameter
Description (see paragraph
6.5.1)
Example
Remarks
ON
OFF
Activation of the transmission
test option only
(see paragraph 6.5.1)
ON
CLIP
Altering the transmission test
type to CLIP
(see paragraph 6.5.1)
CLIP
- After the activation of
transmission test, the type is set
to SMS sending by default