Installation and operating manual: NEO/NEO-PS v.1.4S EN
Marking this option authorizes the telephone numbers entered in the NUMBERS tab to control the output with
the ACTIVATE VIA CLIP option marked.
Selecting this option makes EVERY module to control the output when connecting via any telephone number.
REMARKS:
•
it should be remembered, that the number via which we want to control the output can
not be “unlisted”.
•
reactions to an incoming call are configured in the OPTIONS bookmark
6.4.3 ACTIVATING INPUTS/OUTPUTS
This tab is used to configure the mask of inputs/outputs for the output with the INPUT/OUTPUT VIOLATION
option selected.
The module enables controlling a given output by using the selected inputs/outputs and one of four logical
functions:
logical function 'and'
(AND,
AB
Y
=
, where Y = output, A/B = input/output).
It is a logic circuit which has the following functions: Signal value “1” is present at the output, only if both
input signals have the logical value “1”.
A
B
Y
0
0
0
0
1
0
1
0
0
1
1
1
logical function 'or'
(OR,
B
A
Y
+
=
, where Y = output, A/B = input/output).
It is a logical sum circuit which generates the signal value “1” at the output, if at least one of the signals has
the same value. It means that “0” appears only when both signals have “0” value.
A
B
Y
0
0
0
0
1
1
1
0
1
1
1
1
logical function 'nor'
(NOR,
B
A
Y
+
=
, where Y = output, A/B = input/output).
It is a logic circuit which has the signal value “1” at the output only when all signals are “0”
A
B
Y
0
0
1
0
1
0
1
0
0
1
1
0
22