Installation and operating manual: NEO/NEO-PS v.1.4S EN
6.2.4 NOTES
This field is not recorded in the module, but only serves as an information note. It is recorded only in
the configuration file on the service computer.
6.3 INPUTS (bookmark)
Input configuration, module reactions to violations and restores to a normal state, can be set in this
boo
kmark. The module has got eight inputs on the main board.
6.3.1 MGSM INPUTS
●
POLARITY
:
The inputs of the module can be independently configured with many types
of
polarities
(configurations):
I1-I6: NO, NC, EOL, 2EOL/NO, 2EOL/NC, OFF
I7-I8: NO, NC
trigger by GND (0V VDC ) or lub „plus” (+VDC) according to
JI7, JI8
settings.
●
NO –
denotes the GND level triggered signal (0V DC) NORMALLY OPEN state input. The
I7, I8
inputs
can be triggered by GND (0V DC) or “plus” (+VDC ), depending on the
JI7
and
JI8
settings.
The input in the NORMALLY OPEN state is triggered by
the GND (0V) signal.
The input in the NORMALLY OPEN state is triggered by
the “plus” (+U) signal.”
JI7
is by default (ON)/
NO
in the software
I7
in the NORMALLY OPEN state, is triggered by the
(short circuit) GND signal.
JI7
is (OFF)/
NO
in the software
I7
in the NORMALLY OPEN state, is triggered by
disconnecting “plus” signal
JI8
is by default (ON)/
NO
in the software
I8
in the NORMALLY OPEN state, is triggered by the
GND signal.
JI8
is by default (ON)/
NO
in the software
I8
in the NORMALLY OPEN state, is triggered by the
GND signal.
16
+12V
+
GND