Installation and operating manual: NEO/NEO-PS v.1.4S EN
CONTENT “aaaa”
SMS message is sent as a
transmission test
CONTENT “GSM
Module OK”
“aaaa” = maximum 20
characters
TIME hh:mm
Transmission test time,
according to the option:
“EVERYDAY AT”
TIME 08:30
- Requires adjusting the module
clock
INTERVAL hh
Cycle time between transmission
tests in hours, according to the
option: “EVERY (number of)
HOURS”
INTERVAL 24
- The cycle is counted from
restarting the module or the
RESET TEST command
Example:
yyyy TEST ON CONTENT “GSM Module OK” TIME 3:30 p.m.
yyyy = access code
7.5. Remote configuration of COUNTERS.
The configuration SMS syntax has the following format:
yyyy COUNTER [parameter1 parameter2 parameter3]
Where:
- yyyy = access code;
Parameter
Description (see paragraph 6.5.3)
Example
Remarks
SMS xx
The counter determines the maximum number of
SMS messages sent in 24 hours
SMS 40
xx = a number
between 1 and 99
FAILURE xx
The counter determines the maximum number of
sent SMS messages with failure information
FAILURE 10
xx = a number
between 1 and 20
SMSATTEMPTS
xx
The counter determines the number of attempts
for sending a SMS message corresponding to a
particular problem
with transmission (for example: temporary lack
of GSM range)
SMSATTEMPTS
10
xx = a number
between 1 and 20
ex.
yyyy COUNTER SMS 40 FAILURE 10 SMSATTEMPTS 3
yyyy = access code
7.6. Remote configuration of TIMES.
The configuration SMS syntax has the following format:
yyyy TIMES [parameter1 parameter2 parameter3]
Where:
- yyyy = access code;
Parameter
Description
Example
Remarks
CALL xx
The parameter determines the
maximum time of a telephone
connection (VOICE-type connection)
CALL40
xx = a number between 1 and
46 seconds
ENTRY xx
The parameter determines the time
of entering for the DELAYED input
(for the alarm control panel
function)
ENTRY 15
xx = a number between 1 and
600 seconds
EXIT xx
The parameter determines the time
of exiting for the alarm control
panel function
EXIT 30
xx = a number between 1 and
600 seconds
ACLOST xxx
The parameter determines the time
of delay for signaling “no AC
supply”
ACLOST 060
xxx = a number between 0
and 999 minutes
ex.
yyyy TIME OF CALL 40 ENTRY 15 EXIT 3 ACLOST 060
yyyy = access code
41