11.2.4.3 Retro-fitting the cable driver module
Retrofit
1: Cable driver
module
Fig. 88: Retro-fitting the cable driver module
•
Loosen all cable plugs and the 4 fixing screws.
Every screw connection consists of an M3 screw, a toothed washer and a flat washer.
•
Do not lose any parts, danger of short-circuit.
•
Note:
Older units are equipped with a flat plug at the lower right screw joint.
Do not forget this when mounting the driver module.
•
Replace every screw by one of the provided spacer bolt.
•
Plug-on the cable driver module.
Take care that every connector at the module gets into the corresponding contact on the
eddy current module.
•
Fasten the module with the remaining screws.
•
For older units: re-attach the flat plug for the shielding connection.
•
Re-plug all cables onto the cable driver module.