Manual
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
B0059001 / Rev. 2.3
Maintenance
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
129
10.4 Program status / Operational status
Program status
Operational status
Inactive
System start
Program invalid
Inactive
System configuration invalid
Automatic
Ready
Active
Program change
Program invalid
Error
Done
Inactive
System configuration invalid
Section active
Setup
Edit
Active
Program change
Error
Program invalid
Measurement stopped
Inactive
System configuration invalid
Speed meas. finished
X/Y active
X/Y sampling done
Section active
Wait for PLC
Pos: 116 /Schweissnaht/Gerä te/SND40/10 Wa rtung/Betriebszustände Automatik @ 0\mod_1131962884906_501.do cx @ 953 @ 3 @ 1
10.4.1 Operational conditions in program status „Automatic“
Ready:
Neither a program change nor a detecting job is active. The unit is ready for
the next job or program change via PLC. The operator can use the keys
“
”, “
Statistics
”, “
Program
” or “
System
”.
Active:
A detecting job was started by the PLC. This operational condition will be
automatically terminated, as soon as the positioning procedure has been
performed. When no error condition is existing, the condition changes over
to “
Ready
”.
Program change:
A program change was started by the PLC. This operational condition will be
automatically terminated, as soon as the change has been performed by the
PLC, also if a change was not possible since a non-existing program number
was selected. Then a message is released which will be displayed in the
“error message” field.
Note
: In this case the unchanged program number will be mirrored back at
the PLC interface, since the change was not possible.
Error:
A started detecting job cannot be executed. An operator intervention is
required to redress this condition. The cause for this condition may be
internal or external disturbances which do not redress themselves. In the
field “
error message
” the triggering error message is shown.
Pos: 117 /Schweissnaht/Gerä te/SND40/10 Wa rtung/SND40 Sto re @ 4\mod_1554462014343_501.docx @ 46099 @ 23334444 @ 1