9.26 Sensor cable SKNS8S
Usage: Connecting the combo sensors and the leakage flux sensors to the sensor switch box.
The cable has a cable socket at the sensor side, and a cable plug at the control unit side.
Standard cable length is 5 meters, other lengths must be specified.
1 :
white
+12 V
1 :
white
+12 V
2 :
green
-12 V
2:
green
-12 V
3 : brown
(+blue)
*
AGND
3 : brown
(+blue)*
AGND
4 :
yellow
Meas.
4 :
yellow
Meas.
signal 1
signal 1
5 :
red
Meas.
5:
red
Meas.
signal 2
signal 2
6 :
grey
+coil
6 :
grey
+coil
7 :
pink
-coil
7 :
pink
-coil
**8 :
blank
shield
**8 :
blank
shield
Control unit side
Sensor side
cable plug
8
7
6
6
7
8
cable socket
(Harting HAN8)
2
1
5
5
1
2
(Harting HAN8)
3
4
4
3
Fig. 65: SKNS8S
Cable diameter: 8.7 mm
Structure:
8 × 0.5 mm
2
, LiYCY
Bending radius: 54 mm: laid fixed, 130 mm: laid flexible
Please observe the notes (*, **) for sensor cable KNS9S. These are identic to the sensor
cable SKNS8S!
Pos: 104 /Schweissnaht/Kabel/CECM18S-G @ 0\mo d_1129209953109_501.do cx @ 818 @ 2 @ 1