Manual
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
B0059001 / Rev. 2.3
Communication with the PLC
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
59
The fieldbus can be switched off. Then the unit is like an I/O SND40.
Description
1. Select the parameter
"Fieldbus"
with the
↑
key.
2.
Set the parameter
"Fieldbus"
with the + key to ON
3.
Close the keyboard
(input panel) with the
< keyboard > key.
Fig. 34: SND40 Fieldbus On
5.2.5 GSD file for Profibus
The GSD file contains specific configuration data of the Slaves. The data must be known to the
Profibus Master. The manufacturers of the Profibus master supply the tools for integrating the GSD
file into the Profibus network. For example, the Siemens “step 7 Tools” are suitable for this.
ROLAND ELECTRONIC does not supply such tools, since they must be orientated according to
the interface conception of the masters.
The GSD file is supplied on a CD or can be downloaded from the ROLAND ELECTRONIC
homepage.
5.2.6 GSD file for ProfiNet IO
The GSD file contains the specific configuration data of the device. The data must be known to the
Profibus controller. The manufacturers of the Profibus controller supply the tools for the integration
of the GSD file into the Profibus network. Roland Electronic does not supply such tools, because
they have to be compatible with the interface design of the controller.
The GSD file is supplied on a CD or can be downloaded from the ROLAND ELECTRONIC
homepage.