Manual
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Technical data
B0059001 / Rev. 2.3
116
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
9.23 Eddy current probe EC4x40IRF50-400-S
Technical data
Application:
Round material
Flat material
Diameter of tube:
unlimited
Wall thickness:
Depending on material
Measuring principle:
Eddy current (high resolution)
Arrangement:
radial
Width of track:
1 mm
Width of measuring patch:
1.5 mm
Ambient temperature:
10 - 40° C (50 – 104°F) (operation)
Class of protection:
IP65
Weight:
0.15 kg (0.33 lbs.)
Material of enclosure:
Stainless steel
Sensor cable:
CECM18S-G
Sensor Connection Box:
SCB-EC-S
Description
1: View – active area
2: Direction of material
flow
3: Marking
4: Sleeve Ø 5 x 0.5
made of INOX
5: Cable plug
Order no.: 2277704
All dimensions in mm.
Abb. 61: EC4x40IRF50-400-S
Pos: 100 /Schweissnaht/Sensore n/EC (Wirbe lstromso nden)/EC5x30IF10-100- S @ 0\mod_1129558473328_501.docx @ 844 @ 2 @ 1
Ø
20
2
1
3
4
5
2
SW14
SW18
62
Ø
4
5
20
62
±0
,5
1
00
0
Ø
20
52