Standard wiring of interface
Operational condition: Setup – Edit (X/Y)
Condition!
1.
The unit must be in
”Setup - Edit
“ condition.
2.
System parameter
”Test job control mode: KM
“ (by SND40 key)
3.
X/Y operation (started / terminated by key operation).
4.
The PLC must already have the tube prepared for rotation. The PLC must then accordingly output the signal "motor"
to rotate the tube.
Key
/ Start
Key
/ Stop
Parallel Data Outputs
1)
OUT0
/ Start Test job active
OUT2
/ Ready for measuring
OUT3
/ Setup active
OUT5
/ General fault
OUT7
/ Motor
t1: < 100 ms
t2: The user will terminate the X/Y operation with the <
Stop
> key.
t3: < System parameter
”time
“
t4:
≥
0 ms
t5: > 30 ms
The total duration of the X/Y operation will be determined via key operation by the user.
1)
Not mentioned inputs / outputs of the interface are not required for parameter programming.