Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Mounting
B0059001 / Rev. 2.3
32
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Therefore, the probe should only be mounted in positions where the material structure is
undisturbed.
Note:
Scratched or coarse surfaces also lead to strong interference signals.
The eddy current probe is defined for a defined direction of material flow. This means, the probe
must be mounted according to the technical drawing.
Note:
If a probe is mounted 90° rotated, the measuring signal will be remarkably worse.
The stated track width is then no longer correct.
Pos: 22 /Schweissnaht/ Geräte/ SND40/4 Montage/Monta ge des Auswe rtegerä tes SND40 @ 0\mo d_1143112382078_501.do cx @ 1927 @ 2 @ 1
3.3
Mounting the SND40 Control Unit
The control unit must be mounted such it can be monitored and easily operated during production.
The place where the unit is mounted is to be safely accessible and clearly arranged. For service
purposes it might be required to open the door from the rear. Attention must be paid to this fact
when mounting the unit.
Ideally the unit is mounted at a place from which the sensor can be watched.
Note:
The unit must not be mounted within danger zones, otherwise operating and
monitoring the unit is no longer possible without endangering.
The unit must not be exposed to extreme temperature, radiation or mechanical load.
The enclosure (Rittal, Type CP 6531.200) is prepared for the support arm system CP-L (round).
The connection for the support arm is at the bottom side.
Note:
CAD files are available from Rittal in dxf and dwg format. The files can also be
found on the Rittal CD-ROM "RiGeo" (Part No. SZ 2406.100). issue Febr. 2006.
Suitable components such as enclosure couplings, floor mounts, connecting adapters, inclination
adapters and support arms are available from the Rittal Company.