Manual
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Technical records
B0059001 / Rev. 2.3
146
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Minimal wiring of interface
Operation condition: Setup – Edit (X/Y)
Condition!
1.
The unit must be in ”
Setup - Edit
“ condition.
2.
System parameter ”
Test job control mode: KM
“ (by SND40 key)
3.
X/Y operation (started / terminated by key operation).
4.
The PLC must already have the tube prepared for rotation. The PLC must then accordingly output the signal "motor"
to rotate the tube.
Key / Start
Key / Stop
Parallel Data Outputs
1)
OUT2 / Ready for measuring
OUT5 / General fault
OUT7 / Motor
t1: < 100 ms
t2: The user will end the X/Y operation with the <
Stop
> key.
t3: < System parameter ”
time
“
t4:
≥
0 ms
The total duration of the X/Y operation will be determined via key operation by the user.
1)
Not mentioned inputs / outputs of the interface are not required for parameter programming.
t1
t2
t4
t3