Manual
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Technical data
B0059001 / Rev. 2.3
110
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Description
1 Output for supplying the sensor
2 Input for controlling by the
SND40
3 Connecting terminals for the
supply voltage (mains voltage),
with built-in fuse (3.15 A
medium-blow)
Brown = L
blue = N
green/yellow = PE (ground)
Always connect the safety lead
(PE) !
4 Adjuster for output voltage
(behind screw)
5 Cable infeed fitting for supply
voltage
6 Control connection assignment
(valid from serial number C1211)
Fig. 55: Connections and components