Roche Diagnostics
E-18
Operator’s Manual · Version 3.1
13 ISE operation
Cedex Bio System
Daily operation
8
Performing controls
Performing
Default QC
1. Start the wizard.
Overview
>
Order
>
2. Select a control and place the tube.
Repeat until there are no controls left
on the screen.
n/a
3. Start the QC measurement.
4. Validate the QC results.
Workplace
>
QC Status
>
5. Remove the controls.
n/a
Performing an individual
QC measurement
1. Start the wizard.
Workplace
>
QC Status
>
2. Select a test.
n/a
3. Select a control and place the tube.
Repeat until there are no controls left
on the screen.
n/a
4. Start the QC measurement.
5. Validate the QC results.
Workplace
>
QC Status
>
6. Remove the control.
Performing all
due QC measurements
1. Start the wizard.
Overview
>
Order
>
>
2. Select a control and place the tube.
Repeat until there are no controls left
on the screen.
n/a
3. Start the QC measurement.
4. Validate the QC results.
Workplace
>
QC Status
>
5. Remove the controls.
9
Finishing the shift
1. Check for unfinished orders.
Workplace
>
Orders
Choose
>
Not Finished
2. Check for non-validated results.
Workplace
>
Result Review
Choose
>
Not Accepted
3. Check for non-transmitted results.
(If working with a host system only.)
Workplace
>
Result Review
Choose
>
Not Sent to Host
4. Start the
End Shift
wizard.
Overview
>
End Shift
5. Perform the daily backup.
Utilities
>
Export
>
Database
6. Export the full results.
Utilities
>
Export
>
Results
7. Clean up the database.
Workplace
>
Orders
>
Workplace
>
Result Review
>
Workplace
>
QC Status
>
Workplace
>
QC History
>
Workplace
>
Calibrations
>
8. Perform the maintenance actions
that are due.
Utilities
>
Maintenance
9. Check the external fluid containers.
Overview
>
>
10. Log off the system.
Overview
> button with your user name
11. Shut down the system and switch off
the instrument (if last shift).
n/a
n/a
Task
Steps
Navigation
With wizard As individual steps
Table E-3
Overview of the daily operation tasks
Summary of Contents for Cedex Bio
Page 1: ...Cedex Bio System Operator s Manual Software Version 2 1...
Page 10: ......
Page 22: ...Roche Diagnostics A 14 Operator s Manual Version 3 1 1 Safety Cedex Bio System Safety labels...
Page 130: ...Roche Diagnostics A 122 Operator s Manual Version 3 1 4 Software Cedex Bio System Buttons...
Page 131: ...5 Daily operation B 3 6 Special operations B 91 7 Configuration B 133 Operation B...
Page 132: ......
Page 303: ...8 General maintenance C 3 Maintenance C...
Page 304: ......
Page 339: ...9 Messages and alarms D 3 10 Result flags D 23 11 Troubleshooting D 39 Troubleshooting D...
Page 340: ......
Page 392: ......
Page 471: ...Glossary F 3 Index F 11 Glossary and Index F...
Page 472: ......
Page 492: ...Roche Diagnostics F 22 Operator s Manual Version 3 1 Index Cedex Bio System...
Page 493: ...Revisions G...
Page 494: ......
Page 495: ...Roche Diagnostics Operator s Manual Version 3 1 G 3 Cedex Bio System 18 Revisions Revisions...
Page 496: ...Roche Diagnostics G 4 Operator s Manual Version 3 1 18 Revisions Cedex Bio System...