TROUBLESHOOTING
INSTALLATION ERRORS
1
2
EJECTOR PIN ISSUES
1.
Pin size, expected pressure,and/or
expected temperature not appropriate
for selected sensor.
•
Refer to “Sensor and Ejector Pin Size” on page
2.
2.
Ejector pin is located behind mold
surface with angle greater than 30°
(
1
at right
)
.
•
Angles greater than 30° cause excessive
side‑load friction and influence sensor
accuracy.
3.
Pin is engraved on head
(
2
at right
)
.
•
Pin heads must remain flat. Engrave pins on
the side if necessary.