SENSOR INSTALLATION CHECK—EJECTOR PLATE INSTALLATIONS
Verify that the each sensor, transfer pin, and ejector pin pocket is machined correctly.
PRE‑ASSEMBLY CHECKS
1.
Indentation Test (with Ejector Pin)
With the ejector pin installed, push on the ejector pin; verify the clearance of 0.012” (0,3 mm (or
1/5 part thickness)) exists between the bottom of the ejector pin head and the ejector plate surface
.
2.
Flush Test (with Sensor)
With the sensor installed in the ejector retainer plate, verify that the counterbore depth equals
(0,5mm) (if needed) and the counterbore diameter is larger than the ejector pin head. The sensor
head should be flush with the ejector retainer plate.
POST‑ASSEMBLY CHECK
1.
Flush Test (Full Stack)
With the sensor and ejector pin installed, and the ejector plate in the injection position, fixed
towards clamp plate, the ejector pin should be flush with the ejector plate/cavity surface.
Ejector Retainer Plate
Ejector
Retainer Plate
B Plate or Cavity
Insert
Ejector Plate
Ejector Plate
Ejector
Plate
Clamp Plate
Clamp Plate
Ejector Pin
Sensor
Sensor
Ejector Pin
Summary of Contents for Lynx LS-B-127-125
Page 2: ...PRINT DATE 07 21 2020 REVISION NO 0...
Page 6: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual iv RJG Inc...
Page 8: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual vi RJG Inc...
Page 14: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual 6 RJG Inc...
Page 58: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual 50 RJG Inc...
Page 65: ......