Lynx™ Strain Gage Button Sensors LS‑B‑127‑50/125/500/2000 | Product Manual
52
RJG, Inc.
1
3
2
4
SENSOR HEAD ISSUES
INSTALLATION ERRORS (
continued
)
1.
Ejector Pin head diameter is larger than
sensor pocket diameter
(
1
at right
)
.
•
Counterbore the ejector plate, or chamfer the
pin head to ensure that the pin rests only on
the sensor nub.
2.
Sensor head is installed incorrectly
(
2
at right
)
.
•
The sensor nub must face the ejector pin.
DO NOT install the sensor head upside‑
down.
3.
Sensor pocket surface is not smooth
(
3
at right
)
.
•
The mold surface must have a finish of
32
or
better; the sensor pocket must have a smooth
surface.
4.
Sensor and ejector pin are not
perpendicular
(
4
at right
)
.
•
The sensor and ejector pin must be
perpendicular.