Lynx™ Strain Gage Button Sensors LS‑B‑127‑50/125/500/2000 | Product Manual
42
RJG, Inc.
3.
Indentation Test (with sensor)
With the clamp plate disassembled, sensor in place, and cover plate removed, push the sensor and
transfer pin forward; there should be 0.012–0.02” (0,3–0,5 mm) clearance between the sensor
bottom and the clamp plate/sensor pocket bottom before the cover plate surface.
Verify that the pin moves freely without any resistance.
4.
Flush Test (Full Stack)
With the sensor, ejector, and transfer pin installed, and the ejector plate in the injection position,
fixed towards clamp plate, the ejector pin should be flush with the ejector plate/cavity surface.
SENSOR INSTALLATION CHECK—CLAMP PLATE (HEAD‑TO‑HEAD) INSTALLATION
(
continued
)
Clamp Plate
Ejector Plate
Transfer Pin
Sensor
Ejector
Retainer
Plate
Clamp
Plate
Cover
Plate
Ejector
Plate
B Plate
or
Cavity
Insert
Ejector Pin
Transfer Pin
Sensor