Product Manual | Lynx™ Strain Gage Button Sensors LS‑B‑127‑50/125/500/2000
RJG, Inc.
23
INSTALLATION SPECIFICATIONS (
continued
)
2
1
3
4
1
0.25” (6 mm)
2
0.38” (9,5 mm)
3
1.00” (25 mm) for LS‑B‑127‑125/500/2000;
1.6” (40 mm) for LS‑B‑127‑50
4
ø 1.00” (25 mm) MIN
1.
Cable Channel
Machine a cable channel width of 0.25” (6 mm
[
1
at right
]) with and depth 0.6” (15 mm [
2
at right
]) at entrance and 0.38” (9,5 mm) along
remainder.
2.
Sensor Cable Bend
•
The sensor cable must not be bent within
1.00” (25 mm [
3
at right
]) of sensor head
center for LS‑B‑127‑125/500/2000 models
and 1.6” (40 mm) for LS‑B‑127‑50 model.
3.
Excess Cable Pocket
•
If necessary, a cable pocket may be machined
to store excess cable. This requires 1.00”
(25 mm [
4
at right
]) MIN DIA for the cable
to coil.
SENSOR CABLE CHANNELS