Lynx™ Strain Gage Button Sensors LS‑B‑127‑50/125/500/2000 | Product Manual
20
RJG, Inc.
INSTALLATION SPECIFICATIONS (
continued
)
EJECTOR PLATE INSTALLATION
DETAIL A
B
B
Ʇ
0.001
0.001
(0,03)
(0,03)
A
A
Ʇ
0.001
0.001
(0,03)
(0,03)
0.374” +0.002/‑0.001
9,49 mm
±
0,01
0.02” MIN
(0,5 mm MIN)
IF Part Thickness ≤ 0.05” (1,5 mm),
1/5 of Thickness
IF Part Thickness > 0.05” (1,5 mm),
0.01” (0,3 mm)
Ejector Pin DIA + 0.125” (3 mm)
IF DIA ≥ 0.50” (12,7 mm)
0.01” MIN
(0,3 mm MIN)
0.510” +0.005/‑0.0
13,0 mm
±
0,10
Ejector Pin Head + 0.125” (3 mm)
if DIA ≥ 0.50” (12,7 mm)
R. 0.005” MAX
(0,1 MAX)