
Product Manual | Lynx™ Strain Gage Button Sensors LS‑B‑127‑50/125/500/2000
RJG, Inc.
37
INSTALLATION VALIDATION
SENSOR INSTALLATION CHECK—CLAMP PLATE (TYPICAL) INSTALLATIONS
Verify that the each sensor, transfer pin, and ejector pin pocket is machined correctly.
PRE‑ASSEMBLY CHECKS
1.
Indentation Test (with sensor)
With the clamp plate disassembled, sensor in place, and cover plate removed, push the sensor and
transfer pin forward; there should be 0.012–0.02” (0,3–0,5 mm) clearance between the sensor
bottom and the clamp plate/sensor pocket bottom before the cover plate surface.
Verify that the pin moves freely without any resistance.
2.
Flush Test (with sensor)
With the transfer pin, sensor, and cover plate installed, place the ejector plate above the clamp
plate, and position fully back. Verify that the counterbore depth equals 0.012” (0,3 mm) and that
the diameter is larger than the ejector pin head; the transfer pin should be flush with the ejector
retainer plate.
Clamp Plate
Clamp Plate
Cover Plate
Ejector Plate
Transfer Pin
Transfer Pin
Sensor
Sensor
Summary of Contents for Lynx LS-B-127-125
Page 2: ...PRINT DATE 07 21 2020 REVISION NO 0...
Page 6: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual iv RJG Inc...
Page 8: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual vi RJG Inc...
Page 14: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual 6 RJG Inc...
Page 58: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual 50 RJG Inc...
Page 65: ......