Product Manual | Lynx™ Strain Gage Button Sensors LS‑B‑127‑50/125/500/2000
RJG, Inc.
41
SENSOR INSTALLATION CHECK—CLAMP PLATE (HEAD‑TO‑HEAD) INSTALLATIONS
Verify that the each sensor, transfer pin, and ejector pin pocket is machined correctly.
PRE‑ASSEMBLY CHECKS
1.
Indentation Test (without sensor)
With only the transfer pin installed, push on the transfer pin head and verify a clearance of exists
0.012” (0,3 mm) MIN between the transfer pin head and retainer ejector plate surface.
2.
Indentation Test (with Ejector Pin)
With the ejector pin installed, push on the ejector pin; verify the clearance of 0.012” (0,3 mm (or
1/5 part thickness)) exists between the bottom of the ejector pin head and the ejector plate surface
.
Clamp Plate
Ejector Plate
Transfer Pin
Ejector Retainer Plate
B Plate or Cavity Insert
Ejector Pin