Lynx™ Strain Gage Button Sensors LS‑B‑127‑50/125/500/2000 | Product Manual
8
RJG, Inc.
INSTALLATION OVERVIEW
CLAMP PLATE (TYPICAL) INSTALLATION
Apply the clamp plate (typical) installation to
instances where the ejector and transfer pins
are less than 0.28” (7,0 mm) in diameter.
The sensor connector plate is mounted on the
mold. Pockets and a channel is machined into
the mold for the sensor connector, cable, and
sensor head. The sensor head is placed under
the transfer pin above the cover plate in the
clamp plate. The transfer pin is retained below
the ejector pin in the clamp plate. The ejector
pin is retained in the ejector retainer plate and
reaches through to the B‑Plate or cavity insert
(
refer to figure at top right
).
A minimum of 0.50” (12,0 mm) or one‑third of
the transfer pins length, whichever is greater,
must be fitted to a H7/g6 tolerance within the
clamp plate to ensure proper pin alignment
and to prevent possible bending. If 0.50”
(12,0 mm)/one‑third minimum cannot be
achieved, apply the head‑to‑head clamp plate
installation concept (
refer to figure at top right
).
CLAMP PLATE (HEAD‑TO‑HEAD)
INSTALLATION
Apply the clamp plate (head‑to‑head) installation
to instances where the ejector and transfer pins
are greater than 0.28” (7,0 mm) in diameter,
or those in which a minimum of 0.50” (12,0
mm)/one‑third of the transfer pin cannot be
contained above the transfer pin head in the
clamp plate.
The sensor connector plate is mounted on the
mold. Pockets and a channel is machined into
the mold for the sensor connector, cable, and
sensor head. The sensor head is placed under
the transfer pin above the cover plate in the
clamp plate. The transfer pin is retained below
the ejector pin in the ejector plate, while the
ejector pin is retained in the ejector retainer
plate, with both heads resting against each
other. The ejector pin reaches through to the
B‑Plate or cavity insert (
refer to figure at bottom
right
).
CLAMP PLATE (TYPICAL) INSTALLATION
CLAMP PLATE (HEAD‑TO‑HEAD) INSTALLATION
B Plate or
Cavity Insert
B Plate or
Cavity Insert
Ejector
Retainer
Plate
Ejector
Retainer
Plate
Ejector Plate
Ejector Plate
Clamp Plate
Clamp Plate
Cover or
Backing Plate
Cover or
Backing Plate
Sensor
Sensor
Transfer Pin
Transfer Pin
Ejector Pin
Ejector Pin
Summary of Contents for Lynx LS-B-127-125
Page 2: ...PRINT DATE 07 21 2020 REVISION NO 0...
Page 6: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual iv RJG Inc...
Page 8: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual vi RJG Inc...
Page 14: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual 6 RJG Inc...
Page 58: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual 50 RJG Inc...
Page 65: ......