Lynx™ Strain Gage Button Sensors LS‑B‑127‑50/125/500/2000 | Product Manual
44
RJG, Inc.
2.
Indentation Test (without sensor)
With the ejector and transfer pins installed, the ejector plate in the injection position, and the
ejector plate fixed towards clamp plate, press the ejector and transfer pin together, away from the
cavity; the ejector pin should recess in the ejector plate 0.008–0.01” (0,2–0,3 mm).
3.
Flush Test (with sensor)
With the sensor, ejector, and transfer pin installed, and the ejector plate in the injection position,
fixed towards clamp plate, the ejector pin should be flush with the ejector plate/cavity surface.
SENSOR INSTALLATION CHECK—CLAMP PLATE (HEAD‑TO‑HEAD) INSTALLATION
(
continued
)
Ejector
Retainer
Plate
Ejector
Retainer
Plate
Clamp
Plate
Clamp
Plate
Ejector
Plate
Ejector
Plate
B Plate
or
Cavity
Insert
B Plate
or
Cavity
Insert
Ejector Pin
Ejector Pin
Transfer Pin
Transfer Pin
Sensor