SENSOR INSTALLATION CHECK—CLAMP PLATE (TYPICAL) INSTALLATION (
continued
)
POST‑ASSEMBLY CHECKS
1.
Protrusion Test (without sensor)
With the ejector and transfer pins installed, the ejector plate in injection position, and the ejector
plate fixed towards clamp plate, press the ejector and transfer pin together, towards the cavity; the
ejector pin should protrude 0.008–0.01” (0,2–0,3 mm).
Ejector
Retainer
Plate
Clamp
Plate
Ejector
Plate
B Plate
or
Cavity
Insert
Ejector Pin
Transfer Pin