Product Manual | Lynx™ Strain Gage Button Sensors LS‑B‑127‑50/125/500/2000
RJG, Inc.
27
INSTALLATION SPECIFICATIONS (
continued
)
2.
Ejector Plate Installations
The Lynx sensor case is mounted perpendicular/side‑facing (is rotated 90° from the direction which
the mold moves for ejector plate installations to prevent damage to sensor components. Install the
Lynx sensor case on the outside of the mold using the provided socket head cap screws 8‑32 x
1.75” (M4—
not provided by RJG
).
8‑32 (M4
[4 Places])
0.688”
(17,5 mm)
0.6”
(15 mm)
1.000”
(25,40 mm)
0.12”
(2,9 mm)
3.0” MIN (76 mm MIN)
Lynx Case to Stay within
Edge of Ejector Plate
CAUTION
There must be 3.0” (76 mm) MIN
from mounting location opposite to Lynx connector
to end of ejector box or mold to prevent overhang
of connectors.
LYNX CASE MOUNTING