Product Manual | Lynx™ Strain Gage Button Sensors LS‑B‑127‑50/125/500/2000
RJG, Inc.
53
INSTALLATION ERRORS (
continued
)
2
3
1
CASE AND CABLE ISSUES
1.
Sensor cable is pinched during mold
assembly
(
1
at right
)
.
2.
Sensor case is mounted on surface that
exceeds temperature rating.
•
Do not mount the Lynx case on surface that
exceeds the recommended temperature
rating. Contact RJG, Inc. Customer support
for high‑temperature applications.
3.
Lynx case is drilled to accommodate
alternate mounting
(
2
at right
)
.
•
NEVER drill the Lynx case. Failure to comply
will result in damage or destruction to
equipment and void of warranty.
4.
Orientation of Lynx connector on Lynx
case is altered from OEM
(
3
at right
)
.
•
The Lynx connector on the Lynx case is
keyed. DO NOT attempt to change key
orientation by loosening or tightening the Lynx
connector on the Lynx case. Failure to comply
will result in damage to equipment and void of
warranty.
Summary of Contents for Lynx LS-B-127-125
Page 2: ...PRINT DATE 07 21 2020 REVISION NO 0...
Page 6: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual iv RJG Inc...
Page 8: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual vi RJG Inc...
Page 14: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual 6 RJG Inc...
Page 58: ...Lynx Strain Gage Button Sensors LS B 127 50 125 500 2000 Product Manual 50 RJG Inc...
Page 65: ......