Power off the Perforex machine and lock out using the appropriate lock out/tag out
procedures.
Remove motor servo and encoder cables. Secure them safely to the side of the motor to
ensure they do not get damaged.
Loosen the motor-gearbox coupling using a 5mm Allen wrench (See Figure 3).
Loosen the four mounting bolts that secure the motor to the gearbox. Only one can be
seen from the photo below.
Carefully slide the Y-Axis motor off the gearbox coupling.