57
o
If you cannot get a Tool Clamped signal, remove sensor S1 and place a metal object near the
tip of the sensor.
If a signal “Tool in Spindle Clamped” is received, the sensor S1 needs to be adjusted. See
the adjustment below.
If a signal is not received, swap sensor S2 with S1 (only for testing, do not install into the
spindle) and test for Tool Clamped signal. If a signal is received, sensor S1 has failed.
If a “Tool in Spindle Clamped” is still not received, mark the rotation of sensor S5 and
place a metal object near the tip of sensors S1 and S5.
o
Signal received – sensor S5 needs to be adjusted.
o
Signal not received – sensor S5 has failed.
o
Once complete, be sure to install all the sensors with the same original orientation, the
eccentric bushing should match the same rotation as it was before removal.
Note: Proximity sensors #1-4 will all use the same sensor marked #2, sensor #5 will have different
wiring to allow series connection with sensor #1.