30
3.13.2
Servo Drives
The following procedure should be performed on
all drive modules.
Remove all DC bus interconnect bars.
Label motor leads and remove from terminals
X5-U, V, W and PE.
Connect the negative pole (black) of the
Multimeter to the L+ of the DARC and the
positive pole (red) successive against U, V and
W.
In this circuit the multimeter should show a
forward bias of about 0.42v. (Many digital
multimeters make a short beep.)
If the voltage ok, skip to step 3.13.4
If the forward voltage is under 0.42v or a
continuous beep, the diode is likely inoperative.
Reverse the polarity of the multimeter and repeat the measurement above.
When the polarity is reversed, the multimeter should not show a measured value and no
beep should be heard. If it does, one diode is damaged.