33
Servo Power Control Module
3.14.1
Removal
Power down the Perforex machine and properly lock-out the disconnect for safety
Open electrical cabinet
Check for any incoming voltage on the Line Input terminals (Lower right of the electrical
cabinet)
The Power Control Module is located
on the far right of the drive string.
Remove front cover by pushing down
on the cover indentation (below the yellow
caution sticker) and pull cover away from
the Servo Controller. Lift straight up to
disconnect the upper hinge
Disconnect cables from X6 & X10
Note the DIP switch settings for S1
(Address 1) and S2 (Can-Bus Baud rate, 1
Mb/s)
DIP switch 1 should be set with
bottom switch on (left) and all others off
(right)
DIP switch 2, top three on (left) and
all others off (right)
On the top of the controller,
disconnect X20 (Blue/White wires) and the
ribbon cable