SC
[Level]
Symptom
Possible Cause/Required Action
turns on while the polygon
motor is rotating normally.
230
[C]
FGATE: On error [K]
The PFGATE ON signal does
not assert within 5 seconds
after processing the image in
normal job or MUSIC for [K]
starts.
• Defective connection between the controller board
and EGB
• Defective cable between the EGB and LDB
1. Check the connectors.
2. Replace the LDB.
3. Replace the EGB.
231
[C]
FGATE: Off error [K]
• The PFGATE ON signal
still asserts within 5
seconds after processing
the image in normal job
or MUSIC for [K] ends.
• The PFGATE ON signal
still asserts when the next
job starts.
• Defective connection between the controller board
and EGB
• Defective cable between the EGB and LDB
1. Check the connectors.
2. Replace the LDB.
3. Replace the EGB.
232
[C]
FGATE: On error [Y]
The PFGATE register of GAVD
does not assert within 5
seconds after processing the
image in normal job or MUSIC
for [Y] started.
Same as SC 230
233
[C]
FGATE: Off error [Y]
• The PFGATE ON signal
still asserts within 5
seconds after processing
the image in normal job
or MUSIC for [K] ends.
• The PFGATE ON signal
still asserts when the next
job starts.
Same as SC 231
Service Call Conditions
97
4
Summary of Contents for G-P3
Page 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Page 11: ...10...
Page 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Page 91: ...3 Replacement and Adjustment 90 3...
Page 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Page 337: ...5 Service Tables 336 5...
Page 411: ...MEMO 410...
Page 412: ...MEMO 411...
Page 413: ...MEMO 412...