2906 002
LL: RS [FC]
*EGB
[0 to 1275 / 130 / 5%/step]
2906 003
LL: LS [K]
*EGB
[0 to 1275 / 165 / 5%/step]
2906 004
LL: LS [FC]
*EGB
[0 to 1275 / 165 / 5%/step]
2906 005
MM: RS [K]
*EGB
[0 to 1275 / 230 / 5%/step]
2906 006
MM: RS [FC]
*EGB
[0 to 1275 / 150 / 5%/step]
2906 007
MM: LS [K]
*EGB
[0 to 1275 / 245 / 5%/step]
2906 008
MM: LS [FC]
*EGB
[0 to 1275 / 295 / 5%/step]
2906 009
HH: RS [K]
*EGB
[0 to 1275 / 455 / 5%/step]
2906 010
HH: RS [FC]
*EGB
[0 to 1275 / 165 / 5%/step]
2906 011
HH: LS [K]
*EGB
[0 to 1275 / 400 / 5%/step]
2906 012
HH: LS [FC]
*EGB
[0 to 1275 / 290 / 5%/step]
2907
[T2: TC: Size4] Transfer Roller Current: Correction for Humidity, Thick Paper 1, Paper
width between A5 and A6
(Environment, Process Speed, [Color], Paper Side)
LS: Low Speed, RS: Regular Speed, Paper Side: 1st or 2nd
• The value displayed on the LCD is different from these SP's values. For example,
"20%" on the LCD actually means 100%.
2907 001
LL: LS [K]: 1st
*EGB
[0 to 1275 / 150 / 5%/step]
2907 002
LL: LS [K]: 2nd
*EGB
[0 to 1275 / 255 / 5%/step]
2907 003
LL: LS [FC]: 1st
*EGB
[0 to 1275 / 130 / 5%/step]
2907 004
LL: LS [FC]: 2nd
*EGB
[0 to 1275 / 250 / 5%/step]
2907 005
MM: LS [K]: 1st
*EGB
[0 to 1275 / 180 / 5%/step]
2907 006
MM: LS [K]: 2nd
*EGB
[0 to 1275 / 335 / 5%/step]
2907 007
MM: LS [FC]: 1st
*EGB
[0 to 1275 / 150 / 5%/step]
2907 008
MM: LS [FC]: 2nd
*EGB
[0 to 1275 / 270 / 5%/step]
2907 009
HH: LS [K]: 1st
*EGB
[0 to 1275 / 170 / 5%/step]
5. Service Tables
214
5
Summary of Contents for G-P3
Page 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Page 11: ...10...
Page 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Page 91: ...3 Replacement and Adjustment 90 3...
Page 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Page 337: ...5 Service Tables 336 5...
Page 411: ...MEMO 410...
Page 412: ...MEMO 411...
Page 413: ...MEMO 412...