2958
[T2:MH:SP1] Transfer Roller Current: Correction for Humidity, MH Environment, Special
paper1,
(Process Speed, [Color]) LS: Low Speed, RS: Regular Speed
• The value displayed on the LCD is different from these SP's values. For example,
"20%" on the LCD actually means 100%.
2958 001
RS [K]: 1st
*EGB
[0 to 1275 / 100 / 5%/step]
2958 002
RS [K]: 2nd
*EGB
[0 to 1275 / 100 / 5%/step]
2958 003
RS [FC]: 1st
*EGB
[0 to 1275 / 175 / 5%/step]
2958 004
RS [FC]: 2nd
*EGB
[0 to 1275 / 115 / 5%/step]
2958 005
LS [K]: 1st
*EGB
[0 to 1275 / 110 / 5%/step]
2958 006
LS [K]: 2nd
*EGB
[0 to 1275 / 110 / 5%/step]
2958 007
LS [FC]: 1st
*EGB
[0 to 1275 / 120 / 5%/step]
2958 008
LS [FC]: 2nd
*EGB
[0 to 1275 / 120 / 5%/step]
2959
[T2:MH:GL2] Transfer Roller Current: Correction for Humidity, MH Environment,
Glossary paper2,
(Process Speed, [Color]) LS: Low Speed, RS: Regular Speed
• The value displayed on the LCD is different from these SP's values. For example,
"20%" on the LCD actually means 100%.
2959 001
RS [K]: 1st
*EGB
[0 to 1275 / 100 / 5%/step]
2959 002
RS [K]: 2nd
*EGB
[0 to 1275 / 115 / 5%/step]
2959 003
RS [FC]: 1st
*EGB
[0 to 1275 / 130 / 5%/step]
2959 004
RS [FC]: 2nd
*EGB
[0 to 1275 / 130 / 5%/step]
2959 005
LS [K]: 1st
*EGB
[0 to 1275 / 115 / 5%/step]
2959 006
LS [K]: 2nd
*EGB
[0 to 1275 / 125 / 5%/step]
2959 007
LS [FC]: 1st
*EGB
[0 to 1275 / 160 / 5%/step]
2959 008
LS [FC]: 2nd
*EGB
[0 to 1275 / 175 / 5%/step]
5. Service Tables
226
5
Summary of Contents for G-P3
Page 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Page 11: ...10...
Page 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Page 91: ...3 Replacement and Adjustment 90 3...
Page 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Page 337: ...5 Service Tables 336 5...
Page 411: ...MEMO 410...
Page 412: ...MEMO 411...
Page 413: ...MEMO 412...