SC
[Level]
Symptom
Possible Cause/Required Action
The result when the program is
executed in the command
cache is different from
desirable value.
• Insufficient CPU cache
• Insufficient memory process speed
1. Replace the controller board.
2. Replace the RAM DIMM.
[B]
[0709, 070A]: Detailed error code
Even you write the data in the
only cache of memory, the
data is actually written in
another area (not cache) of
memory.
• Defective CPU devices
• Incorrect SPD
• Boot mode setting error
1. Replace the controller board.
2. Replace the RAM DIMM.
[B]
[0801, 0804, 0807, 0808, 0809, 80A]: Detailed error code
An error occurs when
checking the TLB.
• Defective CPU devices
1. Replace the controller board.
[B]
[4002-4005]: Detailed error code
The calculation error in the
CPU occurs.
• Defective CPU
1. Replace the CPU.
821
Self-Diagnostic Error: ASIC
[0B00]
[B]
ASIC error
The write-&-verify check error
has occurred in the ASIC.
• Defective controller board
1. Replace the controller.
[0B06]
[B]
ASIC not detected
The ASIC of the I/O is not
detected.
• ASIC (controller board defective)
• Poor connection between North Bridge and PCI I/
F.
1. Replace controller board.
[0B10]
[B]
SHM register check error
Service Call Conditions
113
4
Summary of Contents for G-P3
Page 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Page 11: ...10...
Page 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Page 91: ...3 Replacement and Adjustment 90 3...
Page 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Page 337: ...5 Service Tables 336 5...
Page 411: ...MEMO 410...
Page 412: ...MEMO 411...
Page 413: ...MEMO 412...