SC
[Level]
Symptom
Possible Cause/Required Action
• Disconnected harness
• Defective high voltage power 1
1. Check the connectors.
2. Replace the PCU for yellow.
3. Replace the drum positioning plate.
4. Replace the high voltage power 1.
325
[D]
Color development motor error
• LOCK signal is not
detected for more than
two seconds while the
motor START signal is on.
• LOCK signal is not
cancelled within two
seconds after the motor is
off.
• Color development motor slip due to the increase of
the load torque
1. Adjust the load torque properly by replacing or
cleaning the development unit.
2. Replace or repair the development motor if the load
torque is normal.
360
[D]
TD sensor: Output maximum error [K]
Vt is more than the maximum
value (4.5) for three times
consecutively.
• Defective connector connection
• Increasing toner density
1. Replace the PCU.
361
[D]
TD sensor: Output maximum error [M]
Same as SC 360
362
[D]
TD sensor: Output maximum error [C]
Same as SC 360
363
[D]
TD sensor: Output maximum error [Y]
Same as SC 360
364
[D]
TD sensor: Output minimum error [K]
Vt is less than the minimum
value (0.5) for three times
consecutively.
• Defective connector connection
• Decreasing toner density
1. Replace the PCU.
4. Troubleshooting
102
4
Summary of Contents for G-P3
Page 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Page 11: ...10...
Page 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Page 91: ...3 Replacement and Adjustment 90 3...
Page 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Page 337: ...5 Service Tables 336 5...
Page 411: ...MEMO 410...
Page 412: ...MEMO 411...
Page 413: ...MEMO 412...