[0 to 60 / 7.5 / 0.1 µA /step]
2357
[Trans.Belt Bias] Transfer Belt Current
([Color], Process Speed) Process Speed -> RS: Regular speed
2357 001
[FC/ K]: RS
*EGB
Adjusts the current that is applied to the transfer belt.
[0 to 60 / 17.0 / 0.1 µA /step]
2357 002
[FC/ M]: RS
*EGB
[0 to 60 / 15.0 / 0.1 µA /step]
2357 003
[FC/ C]: RS
*EGB
2357 004
[FC/ Y]: RS
*EGB
2358
[Trans.Belt Bias] Transfer Belt Current
([Color], Process Speed) Process Speed -> LS: Low speed
Adjusts the current that is applied to the transfer belt.
2358 001
[FC/ K]: LS
*EGB
[0 to 60 / 7.5 / 0.1 µA /step]
2358 002
[FC/ M]: LS
*EGB
[0 to 60 / 6.0 / 0.1 µA /step]
2358 003
[FC/ C]: LS
*EGB
2358 004
[FC/ Y]: LS
*EGB
2402
[Normal: [K]] Transfer roller current and discharge plate voltage for the image area of
plain paper 1 in B/W mode
(Process Speed, Paper Side, Unit) Process Speed -> RS: Regular speed,
Paper Side: 1st or 2nd
Unit -> T.Roll2: Transfer roller, Separa.: Discharge plate (paper separation)
2402 007
RS: 1st: T. Roll2
*EGB
Adjusts the transfer roller current.
[0 to 100 / 18.3/15.5 (NA/EU) / 0.1 -µA/step]
2402 008
RS: 1st: Separa.
*EGB
Adjusts the discharge plate voltage.
[0 to 4 / 2.0 / 0.1 -KV/step]
2402 012
RS: 2nd: T. Roll2
*EGB
[0 to 100 / 18.3/15.3 (NA/EU) / 0.1 -µA /step]
2402 013
RS: 2nd: Separa.
*EGB
[0 to 4 / 2.0 / 0.1 -KV/step]
Service Mode Table
187
5
Summary of Contents for G-P3
Page 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Page 11: ...10...
Page 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Page 91: ...3 Replacement and Adjustment 90 3...
Page 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Page 337: ...5 Service Tables 336 5...
Page 411: ...MEMO 410...
Page 412: ...MEMO 411...
Page 413: ...MEMO 412...