SC
[Level]
Symptom
Possible Cause/Required Action
[B]
[00FF]: Detailed error code
Cache access error in the CPU
• Defective CPU
• Defective local bus
1. Turn the main power switch off and on.
2. Reinstall the system program.
3. Replace the controller board.
[B]
[0601, 0602, 0605, 0606, 0607, 0609]: Detailed error code
Exceptional command does
not operate even though it is
executed on purpose.
• Defective CPU devices
1. Replace the controller board.
[B]
[060A-060E]: Detailed error code
Cut-in command does not
operate when it is executed.
• Defective CPU devices
• Defective ASIC devices
1. Replace the controller board.
[B]
[0610]: Detailed error code
Timer cut-in does not operate
even though it is set.
• Defective CPU devices
1. Replace the controller board.
[B]
[0612]: Detailed error code
Cut-in in ASIC occurs.
• Defective ASIC
• Defective devices in which ASIC detects cut-in.
1. Replace the controller board.
[B]
[06FF]: Detailed error code
The pipeline clock frequency
rate is different from the
prescribed value.
• Defective CPU devices
• Mode bit data error, which is used for initializing
CPU.
1. Replace the controller board.
[B]
[0702]: Detailed error code
4. Troubleshooting
112
4
Summary of Contents for G-P3
Page 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Page 11: ...10...
Page 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Page 91: ...3 Replacement and Adjustment 90 3...
Page 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Page 337: ...5 Service Tables 336 5...
Page 411: ...MEMO 410...
Page 412: ...MEMO 411...
Page 413: ...MEMO 412...