3551 005
Job End 3: [K]
*EGB
In the middle of a job, printing stops and process
control is done if the number of pages in the job gets
to this number.
[0 to 2000 / 500 / 1 page/step]
3551 006
Job End 3: [Cl]
*EGB
3553
[PC SelfChk]
3553 001
Idle Time
*EGB
Adjusts the threshold time for the self check without
the machine operation.
[0 to 24 / 6 / 0.1 Hour/step]
3554
[Pow. ON SelfChk] Power On Self-check
3554 001
Time
*EGB
Adjusts the threshold (Time) of the process control
from turning the power on.
[0 to 24 / 6.0 / 0.1 H/step]
3554 002
Temp./ Humidity
*EGB
Adjusts the threshold (Temperature/ Humidity) of
the process control.
[0 to 100 / 6 / 0.1 g/m
3
/step]
3554 003
Time 2
*EGB
Adjusts the threshold (Time) for developer mixing
after turning the power on.
[0 to 200.0 / 36.0 / 0.1 H/step]
3554 004
Temp./ Humidity 2
*EGB
Adjusts the threshold (Temperature/ Humidity) for
developer mixing after turning the power on.
[0 to 100 / 6.0 / 0.1 g/m
3
/step]
3555
[S.Chk Stand-by] Process Control Self-check Stand-by Time
3555 001
*EGB
Waiting time for the next job command after job
end. If the next job command comes before this
interval expires, the "JOB END 1" process control
is not done. (SP3551 001 and 002)
[0 to 30 / 0 / 1 /sec]
3556
[Image Process.] Display the Time of Last Image Processing
3556 001
Time (Year)
*EGB
[0 to 99 / 0 / 1 year/step]
5. Service Tables
240
5
Summary of Contents for G-P3
Page 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Page 11: ...10...
Page 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Page 91: ...3 Replacement and Adjustment 90 3...
Page 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Page 337: ...5 Service Tables 336 5...
Page 411: ...MEMO 410...
Page 412: ...MEMO 411...
Page 413: ...MEMO 412...