• The value displayed on the LCD is different from these SP's values. For example,
"20%" on the LCD actually means 100%.
2909 001
LL: LS [K]
*EGB
[0 to 1275 / 150 / 5%/step]
2909 002
LL: LS [FC]
*EGB
[0 to 1275 / 130 / 5%/step]
2909 003
MM: LS [K]
*EGB
[0 to 1275 / 180 / 5%/step]
2909 004
MM: LS [FC]
*EGB
[0 to 1275 / 150 / 5%/step]
2909 005
HH: LS [K]
*EGB
[0 to 1275 / 170 / 5%/step]
2909 006
HH: LS [FC]
*EGB
[0 to 1275 / 150 / 5%/step]
2910
[T2: TC2: Size5] Transfer Roller Current: Correction for Humidity, Thick paper 2, Paper
width A6 or less
(Environment, Process Speed, [Color]) LS: Low Speed, RS: Regular Speed
• The value displayed on the LCD is different from these SP's values. For example,
"20%" on the LCD actually means 100%.
2910 001
LL: LS [K]
*EGB
[0 to 1275 / 205 / 5%/step]
2910 002
LL: LS [FC]
*EGB
[0 to 1275 / 165 / 5%/step]
2910 003
MM: LS [K]
*EGB
[0 to 1275 / 265 / 5%/step]
2910 004
MM: LS [FC]
*EGB
[0 to 1275 / 200 / 5%/step]
2910 005
HH: LS [K]
*EGB
[0 to 1275 / 245 / 5%/step]
2910 006
HH: LS [FC]
*EGB
[0 to 1275 / 200 / 5%/step]
2911
[T2: SP Size4] Transfer Roller Current: Correction for Humidity, Special paper, Paper
width between A5 and A6
(Environment, Process Speed, [Color]) LS: Low Speed, RS: Regular Speed
• The value displayed on the LCD is different from these SP's values. For example,
"20%" on the LCD actually means 100%.
2911 001
LL: LS [K]
*EGB
[0 to 1275 / 150 / 5%/step]
5. Service Tables
216
5
Summary of Contents for G-P3
Page 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Page 11: ...10...
Page 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Page 91: ...3 Replacement and Adjustment 90 3...
Page 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Page 337: ...5 Service Tables 336 5...
Page 411: ...MEMO 410...
Page 412: ...MEMO 411...
Page 413: ...MEMO 412...