3601
[Dev. Setup] Developer Initialization Setting
Adjusts the number of the sheet for the developer free run at the developer initializing for
each color.
3601 001
SheetSet: [K]
*EGB
[0 to 100 / 20 / 1 sheet/step]
3601 002
SheetSet: [M]
*EGB
3601 003
SheetSet: [C]
*EGB
3601 004
SheetSet: [Y]
*EGB
3602
[Dev. Setup] Developer Initialization Setting
Adjusts the toner supply times for the developer initializing for each color.
3602 001
SupplySet: [K]
*EGB
[0 to 30 / 20 / 1 /step]
3602 002
SupplySet: [M]
*EGB
3602 003
SupplySet: [C]
*EGB
3602 004
SupplySet: [Y]
*EGB
3606
[Dev. Setup] Developer Initialization Setting DFU
Specifies the maximum times of developer initialization to adjust the proper toner density.
3606 001
Repeat
*EGB
[1 to 20 / 5 / 1 /step]
3611
[Supply Thresh]
Adjusts the toner supply threshold for the toner density adjustment.
3611 001
Normal: [K]
*EGB
[1 to 800 / 420 / 1 V/step]
3611 002
Normal: [M]
*EGB
3611 003
Normal: [C]
*EGB
3611 004
Normal: [Y]
*EGB
3611 005
High Vt:[K]
*EGB
[1 to 800 / 380 / 1 V/step]
3611 006
High Vt [M]
*EGB
5. Service Tables
244
5
Summary of Contents for G-P3
Page 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Page 11: ...10...
Page 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Page 91: ...3 Replacement and Adjustment 90 3...
Page 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Page 337: ...5 Service Tables 336 5...
Page 411: ...MEMO 410...
Page 412: ...MEMO 411...
Page 413: ...MEMO 412...