4. Troubleshooting
Process Control Results
The table below lists the process control results shown in SP 3821.
Number
Result
Notes
10
Success
No error
21
ID sensor correction error
SC 400
22
ID sensor: LED adjustment error
SC 418
31
Charge bias correction error
SC 300 to 307
51
High Vmin (Bk), High K2 (Color) error
SP 3145 (see the note below the
table)
52
Low K2 (Color) error
SP 3146 (see the note below the
table)
53
High K5 error
SP 3147 (see the note below the
table)
54
Low K5 error
SP 3147 (see the note below the
table)
55
High development gamma
Gamma > 5.0 (see the note
below the table)
56
Low development gamma
Gamma < 0.5 (see the note
below the table)
57
Development bias adjustment error
Vk >150V (see the note below
the table)
58
Development bias adjustment error
Vk < -150V (see the note below
the table)
90
No process control
-
99
Not successful
Interrupt during the process
control (e.g. Door open)
91
4